	      <title>Combustion Occurs While Draining In-Service Storage Tanks - Enform Safety Alert #23-2010</title>
	      <link>http://www.maildogmanager.com/page.html?rss=1&amp;client=CPSC&amp;cid=476&amp;email=</link>
	      <description>&lt;h1 align=&quot;left&quot;&gt;&lt;font face=&quot;Verdana&quot; size=&quot;4&quot;&gt;&lt;font size=&quot;2&quot;&gt;Click here to view the complete version of this alert:
  &lt;br /&gt;&lt;/font&gt;&lt;a href=&quot;http://enform.ca/media/102978/sa10_23.pdf&quot;&gt;&lt;font size=&quot;2&quot;&gt;Combustion Occurs While Draining In-Service Storage Tanks&lt;/font&gt;&lt;/a&gt;&lt;/font&gt;
&lt;/h1&gt;
&lt;pre style=&quot;MARGIN: 0.25in 0in 0pt&quot;&gt;&lt;span style=&quot;FONT-FAMILY: 'Verdana', 'sans-serif'&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;&lt;/font&gt;&lt;/pre&gt;
&lt;p&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot; size=&quot;2&quot;&gt;&lt;strong&gt;Description of Incident:&lt;/strong&gt;&lt;/font&gt;
&lt;/p&gt;
&lt;ul&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;On June 11, 2010 an unplanned combustion event occurred at a produced water transfer facility. This event did not result in any personnel injury, however could have resulted in a serious injury or fatality. &lt;/font&gt;&lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;An operations team was draining an out of service tank that was connected to an in service tank. An instrumentation company had bypassed the low level shutdown on the pump between the tanks. The operations team believed this bypass was required to continue draining out of the still in-service tank over the next couple of days.&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;As the out-of-service tank was drained of approximately 350 barrels of produced water, air was drawn in through a vent line to atmosphere. No gas blanket facilities exist at this location and inverting was not considered. &lt;/font&gt;&lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;Shortly after restarting produced water flow into the in-service storage tank, an unplanned combustion event occurred and ensuing fire in both tanks.&lt;/font&gt; &lt;/li&gt;
&lt;/ul&gt;&lt;/span&gt;</description>
	    </item>
		
	    <item>
	      <title>Short Circuit in Connector Assembly Causes H2S Gas Leak - Enform Safety Alert #22-2010</title>
	      <link>http://www.maildogmanager.com/page.html?rss=1&amp;client=CPSC&amp;cid=471&amp;email=</link>
	      <description>&lt;h1 align=&quot;left&quot;&gt;&lt;font face=&quot;Verdana&quot; size=&quot;4&quot;&gt;&lt;font size=&quot;2&quot;&gt;Click here to view the complete version of this alert:
  &lt;br /&gt;&lt;/font&gt;&lt;a href=&quot;http://enformweb01/media/102699/sa10_22.pdf&quot;&gt;&lt;font size=&quot;2&quot;&gt;Short Circuit in Connector Assembly Causes H&lt;sub&gt;2&lt;/sub&gt;S Gas Leak&lt;/font&gt;&lt;/a&gt; &lt;/font&gt;
&lt;/h1&gt;
&lt;pre style=&quot;MARGIN: 0.25in 0in 0pt&quot;&gt;&lt;span style=&quot;FONT-FAMILY: 'Verdana', 'sans-serif'&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;&lt;/font&gt;&lt;/pre&gt;
&lt;p&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot; size=&quot;2&quot;&gt;&lt;strong&gt;Description of Incident:&lt;/strong&gt;&lt;/font&gt;
&lt;/p&gt;
&lt;ul&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;A production well with approximately 29% H&lt;sub&gt;2&lt;/sub&gt;S concentration was prone to tubing hydrate formation during start-ups due to low temperatures, high pressures, high H&lt;sub&gt;2&lt;/sub&gt;S content, and the presence of water and hydrocarbons.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;Because of these ongoing hydrate problems, a triskelion and connector assembly were installed in the well and attached to the production tubing.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;Operations and technical advisors were in the process of entering start parameters into the VFD logic, when a sudden release of gas was heard around the wellhead.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;Through initial observations, it was concluded that the leak was coming from below the master valve but above the wellhead bonnet, and therefore they would be unable to stop the leak.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;A Level 2 emergency was assessed and emergency response procedures were implemented.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
&lt;/ul&gt;&lt;/span&gt;</description>
	    </item>
		
	    <item>
	      <title>Worker Burned by Propane Fire - Safety Alert 10_21 - Enform</title>
	      <link>http://www.maildogmanager.com/page.html?rss=1&amp;client=CPSC&amp;cid=457&amp;email=</link>
	      <description>&lt;a href=&quot;http://www.maildogmanager.com/refer.html?client=##UN&amp;campaign=##CID&amp;from_email=##L@##H&quot;&gt;&lt;font size=&quot;2&quot;&gt;Send copy of this Alert to a friend.&lt;/font&gt;&lt;font size=&quot;4&quot;&gt; &lt;/font&gt;&lt;/a&gt;
&lt;h1 align=&quot;left&quot;&gt;&lt;font face=&quot;Verdana&quot; size=&quot;4&quot;&gt;&lt;font size=&quot;2&quot;&gt;Click here to view the complete version of this alert: &amp;#8201;
  &lt;br /&gt;&lt;/font&gt;&lt;a href=&quot;http://enform.ca/media/94918/sa10_21.pdf&quot;&gt;&lt;font size=&quot;2&quot;&gt;Worker Burned by Propane Fire&lt;/font&gt;&lt;/a&gt;&lt;/font&gt;
&lt;/h1&gt;
&lt;pre style=&quot;MARGIN: 0.25in 0in 0pt&quot;&gt;&lt;span style=&quot;FONT-FAMILY: 'Verdana', 'sans-serif'&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;&lt;/font&gt;&lt;/pre&gt;
&lt;p&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot; size=&quot;2&quot;&gt;&lt;strong&gt;Description of Incident:&lt;/strong&gt;&lt;/font&gt;
&lt;/p&gt;
&lt;ul&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;A propane truck arrived at camp to refill the propane tanks that were mounted on the ends of two trailers, one being a spare sleeper and the other a recreation trailer, both were separate from the camp complex. The propane tanks that were mounted on the trailers were positioned facing each other.&lt;/font&gt;&lt;/font&gt;&lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;The worker filled the tanks on the spare sleeper trailer without incident but the worker noticed an odd smell, moments after starting to fill the recreation trailer.&lt;/font&gt;&lt;/font&gt;&lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;He saw sparks coming from his steel braided hose, which was hooked to propane tank on the recreation trailer and laid across the skid on the sleeper trailer. There was then an immediate fire and the Driver received minor burns to his face. The driver then ran and shut off the propane flow at the truck, got into the cab, and backed the truck away from the fire. The camp crew and water hauler extinguished fire.&lt;/font&gt;&lt;/font&gt;&lt;/li&gt;
&lt;/ul&gt;&lt;/span&gt;</description>
	    </item>
		
	    <item>
	      <title>Workers Hand Caught Between Shank Blocks - Safety Alert sa10_16 - Enform</title>
	      <link>http://www.maildogmanager.com/page.html?rss=1&amp;client=CPSC&amp;cid=458&amp;email=</link>
	      <description>&lt;a href=&quot;http://www.maildogmanager.com/refer.html?client=##UN&amp;campaign=##CID&amp;from_email=##L@##H&quot;&gt;&lt;font size=&quot;2&quot;&gt;Send copy of this Alert to a friend.&lt;/font&gt;&lt;font size=&quot;4&quot;&gt; &lt;/font&gt;&lt;/a&gt;
&lt;h1 align=&quot;left&quot;&gt;&lt;font size=&quot;4&quot; face=&quot;Verdana&quot;&gt;&lt;font size=&quot;2&quot;&gt;Click here to view the complete version of this alert:
  &lt;br /&gt;&lt;/font&gt;&lt;a href=&quot;http://enform.ca/media/94915/sa10_16.pdf&quot;&gt;&lt;font size=&quot;2&quot;&gt;Workers Hand Caught Between Shank Blocks&lt;/font&gt;&lt;/a&gt; &lt;/font&gt;&lt;span style=&quot;FONT-FAMILY: 'Verdana', 'sans-serif'&quot;&gt;
&lt;/h1&gt;
&lt;p&gt;&lt;font size=&quot;2&quot; face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;&lt;strong&gt;Description of Incident:&lt;/strong&gt;&lt;/font&gt;
&lt;/p&gt;
&lt;ul&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;While raising the derrick during rigging up, the top section was scoped up in to position and pinned. The blocks were lowered to the rig floor to remove the scoping lines and cradle from the hook.&lt;/font&gt;&lt;/font&gt;&lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;The Floorhand and Motorhand were trying to open the latch arm of the hook to remove the cradle but the latch arm would not stay open. The Driller went to assist the workers open the latch arm. He positioned himself at the backside of the blocks and placed his left hand on top of the backside of the hook in the shank travel area.&lt;/font&gt;&lt;/font&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;Not realizing that the hook was in the open/loaded position; the Driller used his right hand to assist with pushing the hook latch open, when the shank came free of the obstruction it slammed shut crushing his left thumb.&lt;/font&gt;&lt;/font&gt; &lt;/span&gt;
&lt;/p&gt;</description>
	    </item>
		
	    <item>
	      <title>Workers Hand Caught Between the Sheave and the Deadline - Enform Safety Alert #14-2010</title>
	      <link>http://www.maildogmanager.com/page.html?rss=1&amp;client=CPSC&amp;cid=456&amp;email=</link>
	      <description>&lt;a href=&quot;http://www.maildogmanager.com/refer.html?client=##UN&amp;campaign=##CID&amp;from_email=##L@##H&quot;&gt;&lt;font size=&quot;2&quot;&gt;Send copy of this Alert to a friend.&lt;/font&gt;&lt;font size=&quot;4&quot;&gt; &lt;/font&gt;&lt;/a&gt;
&lt;h1 align=&quot;left&quot;&gt;&lt;font face=&quot;Verdana&quot; size=&quot;4&quot;&gt;&lt;font size=&quot;2&quot;&gt;Click here to view the complete version of this alert:
  &lt;br /&gt;&lt;/font&gt;&lt;a href=&quot;http://enformweb01/media/93946/sa10_14.pdf&quot;&gt;&lt;font size=&quot;2&quot;&gt;Workers Hand Caught Between the Sheave and the Deadline&lt;/font&gt;&lt;/a&gt; &lt;/font&gt;
&lt;/h1&gt;
&lt;h1 align=&quot;left&quot;&gt;&lt;span style=&quot;FONT-FAMILY: 'Verdana', 'sans-serif'&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot; size=&quot;2&quot;&gt;&lt;strong&gt;Description of Incident:&lt;/strong&gt;&lt;/font&gt;
&lt;/h1&gt;
&lt;ul&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;A drilling crew was tripping out of the hole to retrieve a core barrel. They had just pulled two pipe and stopped for a flow check.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;The crew, continued to pull the core barrel. The third pipe was racked back; the derrick hand leaned forward against his positioning lanyard and grabbed the deadline to stabilize the blocks from swinging. The elevators were latched onto pipe #4 and the driller began to hoist.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;The driller looked up to make sure everything was clear and then looked back at the weight indicator. The floor hands were getting the rotary tongs and slips ready. The driller was hoisting in 2nd gear, between ½ - ¾ throttle, so as not to dislodge the core.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;The derrick hand’s hand became caught, between the sheave and the deadline. He yelled to the driller to stop. The blocks were lowered and he was able to remove his hand and climb down to the floor unassisted.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;The driller helped him remove his fall arrest harness and the crew performed first aid. Medics responded and the worker was transported to hospital for surgery. He lost a portion of three fingers on his right hand.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;&lt;/font&gt;&lt;/font&gt;
&lt;/ul&gt;&lt;/span&gt;</description>
	    </item>
		
	    <item>
	      <title>Worker Fatally Injured During Pumpjack Maitenance - Enform Safety Alert #20-2010</title>
	      <link>http://www.maildogmanager.com/page.html?rss=1&amp;client=CPSC&amp;cid=451&amp;email=</link>
	      <description>&lt;a href=&quot;http://www.maildogmanager.com/refer.html?client=##UN&amp;campaign=##CID&amp;from_email=##L@##H&quot;&gt;&lt;font size=&quot;2&quot;&gt;Send copy of this Alert to a friend.&lt;/font&gt;&lt;font size=&quot;4&quot;&gt; &lt;/font&gt;&lt;/a&gt;
&lt;h1 align=&quot;left&quot;&gt;&lt;font face=&quot;Verdana&quot; size=&quot;4&quot;&gt;&lt;font size=&quot;2&quot;&gt;Click here to view the complete version of this alert:
  &lt;br /&gt;&lt;/font&gt;&lt;a href=&quot;http://enformweb01/media/92262/sa10_20.pdf&quot;&gt;&lt;font size=&quot;2&quot;&gt;Worker Fatally Injured During Pumpjack Maitenance&lt;/font&gt;&lt;/a&gt; &lt;/font&gt;
&lt;/h1&gt;
&lt;h1 align=&quot;left&quot;&gt;&lt;span style=&quot;FONT-FAMILY: 'Verdana', 'sans-serif'&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot; size=&quot;2&quot;&gt;&lt;strong&gt;Description of Incident:&lt;/strong&gt;&lt;/font&gt;
&lt;/h1&gt;
&lt;ul&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;While completing maintenance on a pumpjack, a contractor was killed when the arm of the counter weights struck the worker on the side of the head.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;A contract oilfield maintenance company was hired by the operator to install insulation around the pumpjack header system and fuel gas line. The insulation was to be installed on the piping prior to winter freezing.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;The fuel gas line that was to be insulated was positioned below the pumpjack base. The pumpjack was elevated above ground level due to ground elevation issues and wellhead placement.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;During the installation, the worker entered the danger zone and was struck on the head by the pumpjack counter weight arm.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
&lt;/ul&gt;&lt;/span&gt;</description>
	    </item>
		
	    <item>
	      <title>REVISED Sour Gas Leak from Casing Line Failure - Enform Safety Alert #13-2010</title>
	      <link>http://www.maildogmanager.com/page.html?rss=1&amp;client=CPSC&amp;cid=446&amp;email=</link>
	      <description>&lt;p&gt;&lt;a href=&quot;http://www.maildogmanager.com/refer.html?client=##UN&amp;campaign=##CID&amp;from_email=##L@##H&quot;&gt;&lt;font size=&quot;2&quot;&gt;Send copy of this Alert to a friend.&lt;/font&gt;&lt;font size=&quot;4&quot;&gt; &lt;/font&gt;&lt;/a&gt;
&lt;/p&gt;
&lt;h1 align=&quot;left&quot;&gt;&lt;font face=&quot;Verdana&quot; size=&quot;4&quot;&gt;&lt;font size=&quot;2&quot;&gt;Click here to view the complete version of this alert:
  &lt;br /&gt;&lt;/font&gt;&lt;a href=&quot;http://enformweb01/media/89554/sa10_13.pdf&quot;&gt;&lt;font size=&quot;2&quot;&gt;Sour Gas Leak from Casing Line Failure&lt;/font&gt;&lt;/a&gt;&lt;/font&gt;&lt;font face=&quot;Verdana&quot; size=&quot;4&quot;&gt;
&lt;/h1&gt;&lt;/font&gt;
&lt;pre style=&quot;MARGIN: 0.25in 0in 0pt&quot;&gt;&lt;span style=&quot;FONT-FAMILY: 'Verdana', 'sans-serif'&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;&lt;table style=&quot;WIDTH: 100%&quot; cellspacing=&quot;1&quot; cellpadding=&quot;1&quot; align=&quot;middle&quot; border=&quot;1&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td style=&quot;WIDTH: 50%&quot;&gt; &lt;font size=&quot;2&quot;&gt;&lt;strong&gt;Safety Alert&lt;/strong&gt;: #13 - 2010&lt;/font&gt;&lt;/td&gt;&lt;td style=&quot;WIDTH: 50%&quot;&gt; &lt;font size=&quot;2&quot;&gt;&lt;strong&gt;Release Date&lt;/strong&gt;: May 28, 2010&lt;/font&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td style=&quot;WIDTH: 50%&quot;&gt; &lt;font size=&quot;2&quot;&gt;&lt;strong&gt;Incident Type&lt;/strong&gt;: Equipment Failure&lt;/font&gt;&lt;/td&gt;&lt;td style=&quot;WIDTH: 50%&quot;&gt;&lt;font size=&quot;2&quot;&gt;&lt;strong&gt; Country of Origin&lt;/strong&gt;: Western Canada&lt;/font&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/font&gt;&lt;/pre&gt;
&lt;p&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot; size=&quot;2&quot;&gt;&lt;strong&gt;Description of Incident:&lt;/strong&gt;&lt;/font&gt;
&lt;/p&gt;
&lt;ul&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;Two contractors were in the process of obtaining pressure readings from the production casing tubing annulus, when a ¼ inch line off the casing failed and sour gas began leaking to the atmosphere. The break occurred between the valve and the connection to the casing, causing an uncontrolled flow of sour gas, until pumping equipment and kill fluid stopped the flow.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;Kill fluid was pumped down the tubing and the well was brought under control. The Operator and the ERCB deemed the release to be a Level 2 emergency because the well was in close proximity to the Queen Elizabeth Highway 2, as well as some residential and commercial properties.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;Activation of Emergency Operations Centers in response to the incident was required. Notifications and updates were provided to all affected residents, commercial operators, regulatory and government officials. &lt;/font&gt;&lt;/font&gt;&lt;/li&gt;
&lt;/ul&gt;&lt;/span&gt;</description>
	    </item>
		
	    <item>
	      <title>Electric Heater Overheats due to Static Build-up - Enform Safety Alert #12-2010</title>
	      <link>http://www.maildogmanager.com/page.html?rss=1&amp;client=CPSC&amp;cid=442&amp;email=</link>
	      <description>&lt;a href=&quot;http://www.maildogmanager.com/refer.html?client=##UN&amp;campaign=##CID&amp;from_email=##L@##H&quot;&gt;&lt;font size=&quot;2&quot;&gt;Send copy of this Alert to a friend.&lt;/font&gt;&lt;font size=&quot;4&quot;&gt; &lt;/font&gt;&lt;/a&gt;
&lt;h1 align=&quot;left&quot;&gt;&lt;font face=&quot;Verdana&quot; size=&quot;4&quot;&gt;&lt;font size=&quot;2&quot;&gt;Click here to view the complete version of this alert:
  &lt;br /&gt;&lt;/font&gt;&lt;a href=&quot;http://enform.ca/media/88622/sa10_12.pdf&quot;&gt;&lt;font size=&quot;2&quot;&gt;Electric Heater Overheats Due to Static Build-up&lt;/font&gt;&lt;/a&gt;&lt;/font&gt;
&lt;/h1&gt;
&lt;pre style=&quot;MARGIN: 0.25in 0in 0pt&quot;&gt;&lt;span style=&quot;FONT-FAMILY: 'Verdana', 'sans-serif'&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;&lt;table style=&quot;WIDTH: 100%&quot; cellspacing=&quot;1&quot; cellpadding=&quot;1&quot; align=&quot;middle&quot; border=&quot;1&quot;&gt;&lt;tbody&gt;&lt;tr&gt;&lt;td style=&quot;WIDTH: 50%&quot;&gt; &amp;#8201;&lt;font size=&quot;2&quot;&gt;&lt;strong&gt;Safety Alert&lt;/strong&gt;: #12 - 2010&lt;/font&gt;&lt;/td&gt;&lt;td style=&quot;WIDTH: 50%&quot;&gt; &lt;font size=&quot;2&quot;&gt;&lt;strong&gt;Release Date&lt;/strong&gt;: May 27, 2010&lt;/font&gt;&lt;/td&gt;&lt;/tr&gt;&lt;tr&gt;&lt;td style=&quot;WIDTH: 50%&quot;&gt; &lt;font size=&quot;2&quot;&gt;&lt;strong&gt;Incident Type&lt;/strong&gt;: Equipment Failure&lt;/font&gt;&lt;/td&gt;&lt;td style=&quot;WIDTH: 50%&quot;&gt;&lt;font size=&quot;2&quot;&gt;&lt;strong&gt; Country of Origin&lt;/strong&gt;: Canada&lt;/font&gt; , Central Alberta&lt;/td&gt;&lt;/tr&gt;&lt;/tbody&gt;&lt;/table&gt;&lt;/font&gt;&lt;/pre&gt;
&lt;p&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot; size=&quot;2&quot;&gt;&lt;strong&gt;Description of Incident:&lt;/strong&gt;&lt;/font&gt;
&lt;/p&gt;
&lt;ul&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;A Ruffneck FX4 series electric/glycol heater in service in a treatment building experienced a static rupture of the heat exchanger core. No injuries or significant damage resulted from the event and the heater was returned to the manufacturer for analysis.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
&lt;/ul&gt;&lt;/span&gt;</description>
	    </item>
		
	    <item>
	      <title>Workers Hand Partially Amputated From Contact With Fan Blade - Enform Safety Alert #08-2010</title>
	      <link>http://www.maildogmanager.com/page.html?rss=1&amp;client=CPSC&amp;cid=435&amp;email=</link>
	      <description>&lt;p&gt;&lt;a href=&quot;http://www.maildogmanager.com/refer.html?client=CPSC&amp;campaign=464&amp;from_email=##L@##H&quot;&gt;&lt;font size=&quot;2&quot;&gt;Send copy of this Alert to a friend.&lt;/font&gt;&lt;font size=&quot;4&quot;&gt; &lt;/font&gt;&lt;/a&gt;
&lt;/p&gt;
&lt;h1 align=&quot;left&quot;&gt;&lt;font face=&quot;Verdana&quot; size=&quot;4&quot;&gt;&lt;font size=&quot;2&quot;&gt;Click here to view the complete version of this alert:
  &lt;br /&gt;&lt;/font&gt;&lt;a href=&quot;http://enform.ca/media/87216/sa10_08.pdf&quot;&gt;&lt;font size=&quot;2&quot;&gt;Workers Hand Partially Amputated From Contact With Fan Blade&lt;/font&gt;&lt;/a&gt;
&lt;/h1&gt;&lt;/font&gt;
&lt;pre style=&quot;MARGIN: 0.25in 0in 0pt&quot;&gt;&lt;span style=&quot;FONT-FAMILY: 'Verdana', 'sans-serif'&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;&lt;/font&gt;&lt;/pre&gt;
&lt;p&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot; size=&quot;2&quot;&gt;&lt;strong&gt;Description of Incident:&lt;/strong&gt;&lt;/font&gt;
&lt;/p&gt;
&lt;ul&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;A maintenance worker was performing routine housekeeping activities in a generator building. As the worker was cleaning the building walls, he noticed a small amount of oil below the generator fan guard.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;The worker folded a small rag and attempted to clean the area, while the generator was running. A small opening on the fan guard, which allows for removal of the guarding during servicing, allowed the rotating fan blades to grab the rag, which pulled the workers hand into fan blades.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;This resulted in a partial amputation of the workers hand.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
&lt;/ul&gt;&lt;/span&gt;</description>
	    </item>
		
	    <item>
	      <title>Drilling Rig Proportional Brake Fails - Enform Safety Alert #11-2010</title>
	      <link>http://www.maildogmanager.com/page.html?rss=1&amp;client=CPSC&amp;cid=433&amp;email=</link>
	      <description>&lt;a href=&quot;http://www.maildogmanager.com/refer.html?client=##UN&amp;campaign=##CID&amp;from_email=##L@##H&quot;&gt;&lt;font size=&quot;2&quot;&gt;Send copy of this Alert to a friend.&lt;/font&gt;&lt;font size=&quot;4&quot;&gt; &lt;/font&gt;&lt;/a&gt;
&lt;h1 align=&quot;left&quot;&gt;&lt;font face=&quot;Verdana&quot; size=&quot;4&quot;&gt;&lt;font size=&quot;2&quot;&gt;Click here to view the complete version of this alert:
  &lt;br /&gt;&lt;/font&gt;&lt;a href=&quot;http://enformweb01/media/87213/sa10_11.pdf&quot;&gt;&lt;font size=&quot;2&quot;&gt;Drilling Rig Proportional Brake Fails&lt;/font&gt;&lt;/a&gt; &lt;/font&gt;
&lt;/h1&gt;
&lt;pre style=&quot;MARGIN: 0.25in 0in 0pt&quot;&gt;&lt;span style=&quot;FONT-FAMILY: 'Verdana', 'sans-serif'&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;&lt;/font&gt;&lt;/pre&gt;
&lt;p&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot; size=&quot;2&quot;&gt;&lt;strong&gt;Description of Incident:&lt;/strong&gt;&lt;/font&gt;
&lt;/p&gt;
&lt;ul&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;A rig crew was drilling down a triple stand of drill pipe. When there was 2 meters left of the stand to drill, the top drive started to stall out at 6000 ft/lbs of torque, but the limit was set at 17 000 ft/lbs.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;The VFD computer screen in the doghouse was reading a communication issue. The Motorman and Floorhand began to check the PLC cables in the doghouse for the top drive for damaged lines or loose connections. The driller went up on the man-riding winch to check the PLC cables on the top drive.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
  &lt;li&gt;&lt;font size=&quot;2&quot;&gt;&lt;font face=&quot;verdana,arial,helvetica,sans-serif&quot;&gt;Once into position to look at the cables, the drill console lost power and the top drive crept down 1 meter, then free fell 1 meter until the elevators struck the floor. The draw works continued to un-spool the drill line. When all the drill line unspooled from the drum, it parted from the anchor and became wedged in the line spooler. This prevented the drill line from going to the crown.&lt;/font&gt;&lt;/font&gt; &lt;/li&gt;
&lt;/ul&gt;&lt;/span&gt;</description>
	    </item>
	 

</channel>
</rss>